Suzuki Grand Vitara + General information + Maintenance and lubricant + Heater, ventilation and conditioner + Steering + Suspension bracket + Wheels and tires + Forward driving shaft / bearing of a shaft. Oil epiploon + Driveshafts + Brake system + Engines + Fuel system + System of ignition + System of start + System of release + Transmissions + Coupling + Transfer + Forward and back differentials + Windows, mirrors, locks and security measures. Immobilizer - Electric equipment + Body electric equipment + System of lighting - System of electric equipment + General description + Diagnostics + The works performed on the car - Capital repairs - Generator Removal Installation Dismantling [Type 60 A] Dismantling [Type 70 A and 80 A] Survey [Type 60 A] Survey [Type 70 A and 80 A] Replacement of brushes Assembly [Type 60 A] Assembly [Type 70 A and 80 A] + Specifications Inhaling moments + Tools/information for drivers
|
Survey [Type 60 A]
Rotor
|
Using an ohmmeter, check electric conductance between contact rings of a rotor. If there is no electric conductance, replace a rotor. Standard resistance: 2.5 - 2.9.
Using an ohmmeter, check whether there is no electric conductance between a contact ring and the core of a rotor. If there is an electric conductance, replace a rotor.
Check contact rings whether there is no roughness or a deposit. If they are uneven or there is a deposit, replace a rotor.
|
|
Stator
|
Using an ohmmeter, check electric conductance of all contacts. If there is no electric conductance, replace the stator.
Using an ohmmeter, check whether there is no electric conductance between contacts of the coil and the core of the stator. If there is no electric conductance, replace the stator.
|
1 — the stator 2 — contact of the stator |
|
|
Brush and brush holder
|
Check each brush for wear, having measured its length.
|
If the brush is worn-out to a limit, replace a brush.
Length of a brush of "a"
standard: 16 mm (0.63 inches)
limit: 2 mm (0.08 inches)
|
|
|
Rectifier
|
Using an ohmmeter, check electric conductance between cases of the top and lower rectifiers and contact of each diode.
Check both directions, having changed ohmmeter probes. In each case there has to be only a unilateral conductivity. If result of check unsatisfactory, replace the rectifier.
|
Check unilateral electric conductance between contacts and three diodes similarly described in item 1.
|
|
1 — the rectifier 2 — contact of the diode |
|
|
Condenser
Check condenser capacity. Condenser capacity: 0.5 µF.
|
1 — the rectifier 2 — the condenser |
|
|