Suzuki Grand Vitara SQ416/SQ420/420WD

since 1998 release

Repair and operation of the car



Suzuki Grand Vitara
+ General information
+ Maintenance and lubricant
+ Heater, ventilation and conditioner
+ Steering
+ Suspension bracket
+ Wheels and tires
+ Forward driving shaft / bearing of a shaft. Oil epiploon
+ Driveshafts
- Brake system
   + Brakes
   + Brake highway / hose / main cylinder of a brake
   + Forward brakes
   + Parking and back brake
   - Anti-blocking brake system (ABS)
      + General description
      - Diagnostics
         Precautionary measures at diagnostics of problems
         Table of diagnostics of malfunctions of ABS
         Checks
         Codes of diagnostics of malfunctions
         Scheme of system
         Tables
         Check of the codes of diagnostics of malfunctions (CDM)
         Service of the vehicle
         Check of operation of the hydraulic ABS block
+ Engines
+ Fuel system
+ System of ignition
+ System of start
+ System of release
+ Transmissions
+ Coupling
+ Transfer
+ Forward and back differentials
+ Windows, mirrors, locks and security measures. Immobilizer
+ Electric equipment


9df16362

Table of diagnostics of malfunctions of ABS

See the detailed description of each step in points below.

Step

Action

Yes

No

1

Make the analysis of complaints of the client, confirmation of symptoms of a problem and record KDN. Whether there is a malfunction code?

Pass to a step 2

Pass to a step 5

2

Execute driving check. Whether the malfunction symptom is defined?

Pass to a step 3

Pass to a step 6

3

Check a malfunction diagnostics code. It is a malfunction code?

Pass to a step 4

Pass to a step 5

4

Examine and repair, having addressed the corresponding table KDN. Then execute final check for confirmation after dumping of KDN. Whether there was a problem again?

Pass to a step 7

End

5

Examine the brake system, having addressed the Diagnostic table in the Head the Brake system. Then execute final check for confirmation after dumping of KDN. Whether there was a problem again?

Pass to a step 7

System in good shape

6

Check whether there are no periodically arising problems, having addressed the Section Interrupted or weak connection in the Head the General information and the corresponding chain of codes of malfunctions described in steps 1-3. Then execute final check for confirmation after dumping of KDN. Whether there was a problem again?

Pass to a step 7

System in good shape

7

Check record of codes of malfunction and cleaning. Whether there is a malfunction code?

Pass to a step 2

Pass to a step 5