Adjust height of a pedal of coupling (1), having weakened a lock-nut (2) collars and having turned a bar of a pusher (3). Height of a pedal of coupling is normal if the coupling pedal approximately on 20 mm (0.79 inches) is higher than a brake pedal.
|
After adjustment tighten a lock-nut to the specified value of the moment of an inhaling. Moment of an inhaling (a): 10 N • m (1.0 kg-m, 7.5 pounds feet).
|
|