Suzuki Grand Vitara - General information + Precautionary measures Main precautionary measures Precautionary measures during the work with the catalyst Precautionary measures at service of electric chains - Procedure of check of electric chains Check of a chain on an open condition Check on short circuit (short circuits on weight) The interrupted or weak connection Precautionary measures at installation of means of mobile communication + Identification information The warning, warning and information stickers Places of raising of the car The list of the reductions which are used in this manual + Metric information Standard moments of inhalings + Maintenance and lubricant + Heater, ventilation and conditioner + Steering + Suspension bracket + Wheels and tires + Forward driving shaft / bearing of a shaft. Oil epiploon + Driveshafts + Brake system + Engines + Fuel system + System of ignition + System of start + System of release + Transmissions + Coupling + Transfer + Forward and back differentials + Windows, mirrors, locks and security measures. Immobilizer + Electric equipment
|
Check of a chain on an open condition Possible reasons of an open condition of a chain following: Quite often the reason in the connector or contacts, they have to be in details checked.
Leaky connection in the connector
Weak contact on the plug (because of dirt, corrosion or a rust, hit of foreign objects)
Break in a plait of wires
When checking, chains including electronic control units, such as ECM, TCM, ABS, it is important to carry out a careful inspection, starting with points which easier to check.
|
Disconnect weight from the accumulator.
Check each connector on both ends of the checked chain for weakening of connection. Also check a condition of fixing of the connectors equipped with a clamp.
|
1 check on existence of weak connections 2 the sensor 3 ECM |
Using the test covered contact, check both contacts of the checked chain for pressing of contacts of the covering plug. Check visually each plug for the weakening of contacts (which is perhaps caused by pollution, corrosion, a rust, hit of foreign objects, etc.). Also check that contacts were densely latched in the connector.
|
1 check of tension in contacts by their connection and separation |
By means of the procedures of consecutive check or check of voltage described on the following page check an electrical wiring for break and weak connection of plugs. Find exact location of anomaly if it exists.
|
1 the weakened sinking 2 a gap 3 a thin wire |
|
|
Consecutive check
|
|
Measure resistance between contacts of the connector on both ends of the checked chain (between A-1 and S-1 in the drawing). If continuity was not defined (infinity or excess of a limit), then it means that the chain between the A-1 and S-1 plugs is opened.
|
|
Disconnect the connector which is switched on in a chain (the connector - In in the drawing) and measure resistance between the A-1 and V-1 plugs. If continuity was not defined, then it means that the chain between the V-1 and S-1 plugs is opened or there is an anomaly in the connector Century.
|
|
|
Check of tension
|
If in the checked chain food moves, check of tension can be used for check of a chain.
With all attached connectors and tension given to the checked chain measure tension between each plug and grounding.
If measurements were carried out, and results were as on the list below, then it means that the chain between the V-1 and A-1 plugs is opened.
Tension between:
|
S-1 and weight about 5 V V-1 and weight about 5 In A-1 and weight 0 V |
Also, if the measured values as on the list below, then it means that there is resistance (anomaly) at the level which is responsible for power failure in a chain between the A-1 and V-1 plugs.
Tension between:
|
S-1 and weight about 5 V V-1 and weight about 5 V A-1 and weight 3 V (power failure of 2 V) |
|
|
|
|