|
Audi 100/A61990-1997 of releaseRepair and car operation |
|
Audi 100/A6 + 1. The maintenance instruction + 2. Maintenance service + 3. Engines + 3.2. Diesel engines + 3.3. Removal and a partition of engines + 4. Cooling system + 5. Heating and ventilation + 6. Fuel system + 7. An exhaust system - 8. Systems of start, ignition - 8.1.1. Introduction 8.1.2. Technical characteristics + 8.1.3. The accumulator - 8.1.4. The Generator / system of additional charge of the accumulator 8.1.4.1. Malfunctions of the generator 8.1.5. Replacement of the holder of brushes and a regulator of pressure of the generator 8.1.6. Check of system of start of the engine 8.1.7. A starter 8.1.8. An inlet gas pipeline 8.1.9. A cable of gas/lever throttle заслонки (DB) 8.1.10. A cable of management of gas (DB) 8.1.11. A contour of fuel of the diesel engine 8.1.12. Prestarting heating of diesel fuel 8.1.13. The fuel thermostat 8.1.14. The hydrovalve case 8.1.15. A cable of gas/lever throttle заслонки (ДД) 8.1.16. A cable of management of gas (ДД) + 8.2. Ignition system (petrol engines) + 8.3. System of prestarting heating (diesel engines) + 8.4. System of release of the fulfilled gases + 9. Transmission + 10. Brake system + 11. Suspension brackets, a steering + 12. A body + 13. An electric equipment + 14. A good advice |
8.1.4.1. Malfunctions of the generator
When the control lamp does not die away at normal work of the engine, malfunction, most likely – in the generator. The truth short circuit on a chain site between a control lamp and the generator yields the same result. Also check up by means of the indicator pressure presence on the big socket of the generator. Here it should be always – if it is not present, check up generator connection to the storage battery. If the pressure regulator on your car is located separately from the generator it too can be faulty. In this case it is better to remove the generator and a regulator of pressure and to address to the autoelectrician. The elementary check of a current of loading of the generator is made so: dimensional fires of the car join and the engine is started. If at the working engine fires do not start to burn more brightly this best proof of that the generator does not give a current. If you have a voltmeter, connect it to plugs of the storage battery and start the engine. On the raised turns of idling the generator should develop a current, and the voltmeter – to show about 14 V.Pokazanija differ more than on 1 In? It is faulty either the generator, or a pressure regulator. In many cases constant burning of a control bulb signals about malfunction of the generator, but malfunctions are possible and in other place, and the generator as it is paradoxical, can be serviceable at this time. And nevertheless for the majority of automobile owners a control bulb – a unique indicator of serviceability of the generator. The most often meeting reasons of abnormal functioning of a control lamp of a charge and typical situations are resulted in the table. For example, the line "the Control lamp does not light up" means that ignition should be already included, and at the same time it does not mean that the engine should be started. Malfunctions of the generator are resulted in ascending order probabilities of their occurrence. The malfunctions italicised, have no direct relation to the generator. The table explaining in what can result some of aforementioned malfunctions is more low given. The typical malfunctions reflected by a control lamp of a charge
|
|