Audi 100/A6

1990-1997 of release

Repair and car operation



Audi 100/A6
+ 1. The maintenance instruction
+ 2. Maintenance service
+ 3. Engines
+ 3.2. Diesel engines
+ 3.3. Removal and a partition of engines
+ 4. Cooling system
+ 5. Heating and ventilation
- 6. Fuel system
   + 6.1.2. Technical characteristics
   + 6.2. Multidot system of injection of fuel
   - 6.3. System of injection MPI/MPFI (6-cylinder engines)
      6.3.2. Technical characteristics
      6.3.3. Distinctions of systems of injection
      6.3.4. Gauges
      6.3.5. Idling regulation
      6.3.6. Removal and installation клапанных atomizers
      6.3.7. Check клапанных atomizers
      6.3.8. The oxygen gauge
   + 6.4. The power supply system of diesel engines
   6.5. The device of service of heating
   6.6. Diagnostics of malfunctions of system of heating
   6.7. The conditioner: not only "pluses", but also "minuses"
   6.8. Rules of service of the conditioner
+ 7. An exhaust system
+ 8. Systems of start, ignition
+ 9. Transmission
+ 10. Brake system
+ 11. Suspension brackets, a steering
+ 12. A body
+ 13. An electric equipment
+ 14. A good advice


9df16362

6.3.6. Removal and installation клапанных atomizers
THE GENERAL DATA

SYSTEM OF INJECTION MPI / MPFI

System of injection MPI


1. Returnable топливопровод
2. A bolt, 10 Nanometers
3. A coupling collar
4. A sealing ring
5. A pressure regulator
6. A fuel collector (ring топливопровод)
7. Delivery топливопровод
8. Lock скоба
9. A sealing ring
10. A klapannaja atomizer. Resistance: 15–17 Ohm (омега big).
11. A sealing ring
12. A switched inlet collector

The prevention

Consolidations always replace.


Removal

PERFORMANCE ORDER
1. Remove a hose of inlet air between a measuring instrument mass to the expense of air and гасителем noise.
2. Pull out at coils of ignition of a wire of a high voltage, unhook them from ring топливопровода and put aside.
3. Pull out tips at клапанных atomizers.
4. Turn on ring топливопровод from an inlet collector.
5. Pull out lock скобы клапанных atomizers.
6. Lift ring топливопровод upwards.
7. Take out клапанные atomizers from an inlet collector.

Installation

PERFORMANCE ORDER
1. Klapannye atomizers with new sealing rings insert into an inlet collector. Preliminary sealing rings easily grease with pure engine oil.
2. Establish ring топливопровод.
3. Insert safety скобы клапанных atomizers.
4. Tighten ring топливопровод to an inlet collector the moment of 10 Nanometers.
5. Insert tips клапанных atomizers
6. Thrust high voltage wires in coils of ignition and attach them to ring топливопроводу.
7. Establish a hose of inlet air between a measuring instrument of the mass expense of air and гасителем noise.