      - Codes of diagnostics of malfunctions
         Check of a diagnostic code of malfunctions (KDN)
         Cleaning of a diagnostic code of malfunction (KDN)
         Table of a diagnostic code of malfunction (KDN)
         Information of the scanner
         The terms and formulations used in the scanner
         The table of signals at the exit of the SUZUKI scanner in the test mode
      + General description
   + System of lighting
   + System of electric equipment
   + Tools/information for drivers


9df16362

Cleaning of a diagnostic code of malfunction (KDN)

After repair or replacement of a faulty detail(s) (knot, the mechanism), erase all KDN, having executed the following operations.

Using the SUZUKI scanner

 PERFORMANCE ORDER

    Connect the SUZUKI scanner to the socket of a data transmission channel in the same way, as well as when performing check of DKN. Include ignition. Erase KDN according to instructions on the display of the scanner. For additional information see the Reference book of the mechanic. After KDN is erased, switch off ignition and disconnect the scanner from the socket of a data transmission channel.

Without use of the SUZUKI scanner

 PERFORMANCE ORDER

    Switch off ignition. Using a repair wire (2), connect the feeding plug of the diagnostic socket to the mass of the case (3). Include ignition, at the kept connection described in point 2.
2 — a repair wire
3 — the feeding plug
4 — an air inlet fragment
    Execute 5 cycles of a connection/detachment of a repair wire from "mass" of the case within 10 seconds at an interval of 1 second (the bigger quantity of cycles is admissible) (the wire is connected by other end to the feeding plug of the diagnostic socket).

About — it is opened
S — is closed
T — about 10 seconds